Vortex Measuring Tube VA Di ... ZG2 - Höntzsch

Vortex Measuring Tube VA Di ... ZG2

Vortex Measuring Tube VA Di ... ZG2

Vortex Measuring Tube VA Di ... ZG2 - for small flow rates

Measuring tube VA Di with inside diameter 24 mm.

Probe materials: stainless steel.

Working temperature range up to +100 °C.

Sensor length 150 mm. Process connection with  threaded connection G 1”

Suitable for fixed measuring of actual flow rate V/t [m³/h], flow velocity v [m/s] in clean as well as condensate and particle-laden gases.

Signal evalutaion with integrated transducer UVA.

An additional isolation / supply unit is necessary for ATEX applications category 1/2G and category 1/2D (zone 0, zone 20).

Output signals: 

 

4-20 mA (flow-proportional)quantity pulse / limit value

 

Configurable via RS232 interface and software UCOM.

 

Example for a common application:

Measuring landfill gas

Leakage measurement at large ball valves in gas pipelines

Measuring range

0.4 ... 30 m/s,
0.67 ... 50 m³/h

Pressure resistance

up to 10 bar / 1 MPa overpressure

Media temperature

-40 ... +100 °C

Media

gases

Displayed indicators

flow rate, flow velocity, quantity

IP protection type

IP65 (connection housing)

Type of protection

ATEX category 3G and 3D (zone 2 and 22) (optional)

Sensor output

analog output 4-20 mA, limit value, quantity pulse, RS232 interface