Do you have any questions or need more information? Then please contact us!
In combination with vortex measuring tubes VA TP DN Exactflow II
For measuring gas mass flow, standard flow rate, working pressure and temperature.
Output signals:
parameter setting via RS232 interface with UCOM VTP software and programming adapter
in light metal housing
Measuring range
UVATP – for measuring mass flow rate with sensors VA TP DN Exactflow
Displayed indicators
mass flow rate [kg/h],
standard flow rate [Nm³/h]
actual flow rate [m³/h]
temperature [°C], pressure [hPa], volume/quantity [m³]
IP protection type
IP65
Sensor input
v/VA; t/PT100; p/4...20 mA
Sensor output
analog output, proportional gas mass flow 4 … 20 mA,
relais for limit value or quantity pulse,
vortex output through BNC connector